© 2010 Cypress Solutions Complete Manual: CTM-15X Firmware 1.3.0
Open CTM (Revision D)
112
Command Reference
A cmd save is required for this command to take effect.
See also: pupcond, repaddmes, repdelmes, repemail, replocport, repremip, repremport, repsms, reptype
return to list of commands
pwrmode n
Controls the modem’s power mode.
n = 1 puts the modem in shutdown mode - it can be woken up either by a power cycle, an input alarm
event if configured, or a configured periodic wakeup, see pwrwoe.
n = 2 will power cycle the modem immediately
This command is immediate and does not require a save operation.
Example:
cmd pwrmode 2 this command will power cycle the modem
return to list of commands
pwrsdwn a ddddd
Places the modem into shutdown mode(blinking power LED) based on the state of the modem's standby
signal(ignition).
The ignition state is controlled by the "white" wire of the 3 wire power connection to the modem.
To disable any ignition sense capability connect the "white" wire to the + Voltage "Red" wire.
Default is pwrsdwn 1 10 (modem will switch off based on the standby (ignition) signal state changing with
a 10 second delay before entering shutdown mode).
a = 0 disables the standby signal (ignition) event qualifier
a = 1 enables the standby signal (ignition) event qualifier (default)
ddddd = 10 to 65535 the delay time in seconds after the standby signal event changing state that the
modem will go into power shutdown mode.
The current configuration can be queried by using the pwrsdwn without parameters.
Examples:
Seitenansicht 111