Document #: 001-52039 Rev. *C Page 10 of 24
Software-Controlled STORE/RECALL Cycle
In the following table, the software controlled STORE and RECALL cycle parameters are listed.
[13, 14]
Figure 10. Software STORE/RECALL Cycle: E CONTROLLED
[14]
Figure 11. Software STORE/RECALL Cycle: G Controlled
[14]
NO.
Symbols
Parameter
STK17TA8-25
[1]
STK17TA8-45
Units Notes
E Cont G Cont Alternate Min Max Min Max
26 t
AVAV
t
AVAV
t
RC
STORE / RECALL Initiation Cycle
Time
25 45 ns 14
27 t
AVEL
t
AVGL
tAS Address Setup Time 0 0 ns
28 t
ELEH
t
GLGH
tCW Clock Pulse Width 20 30 ns
29 t
EHAX
t
GHAX
Address Hold Time 1 1 ns
30 t
RECALL
t
RECALL
RECALL Duration 100 100 μs
Notes
13. The software sequence is clocked on the falling edge of E
controlled READs or G controlled READs
14. The six consecutive addresses must be read in the order listed in the Software STORE/RECALL Mode Selection Table W must be high during all six consecutive cycles.